What are some common faults of automatic screw feeding machine?

The automatic screw feeding machine is another achievement of the innovation and development of equipment in the industrial field. Through the innovation of screw binding processing technology and the adoption of more intelligent processing methods, the speed and quality of the original processing efficiency are greatly improved, while saving a lot of labor costs. What problems will occur in the working process of the automatic screw feeding machine? What are the troubleshooting methods for these faults? Today, Gewei Electronics will give a brief introduction.

M3.5 Automatic screw feeding machine

Fault 1: The screw cannot be sucked up or the screw is missing.

1. First, confirm the feeder part of the automatic screw feeding machine to see if there is any phenomenon of screw feeding, and try to take the screw by hand to see if it is in normal working condition.

2. Check whether the vacuum of the automatic screw feeding machine is weakened. The weakening of the vacuum will cause the screw to not be sucked up. If a vacuum problem is found, the vacuum should be removed for cleaning.

3. Check whether the light of the screw sensor of the automatic screw feeding machine is normally on. If the screw does not light up and cause a fault, the sensor needs to be adjusted in time.

4. Check whether the position of the screw suction of the automatic screw feeding machine is offset. If it is necessary to reset the suction position of the system parameters of the automatic screw feeding machine.

Fault 2: The product screw is locked with sliding teeth.

It may be due to the failure of the electric batch torque of the automatic screw feeding machine. First, check whether the current automatic screw feeding machine locking screw torque range is consistent with the electric batch torque, and use the torque meter to test again.

 

Fault 3: screw lock with floating height.

Check whether the locking height in the step setting in the automatic screw feeding machine program reaches the actual screw locking position, and whether the setting of the locking speed parameter is correct.

Fault 4: The position of the lock screw is shifted.

Check whether the position of each coordinate point in the program is accurate, select the coordinate correction function, and recalibrate the coordinates

Fault 5: Equipment crashes.

1. Check whether the automatic screw feeding machine program parameters are set correctly, and restart the equipment after confirming that it is correct

2. Check whether the power supply of the automatic screw feeding machine is abnormal.

The above are some common problems of automatic screw feeding machine and how to solve them. Dongguan Gewei Electronics Co., Ltd. is a senior manufacturer integrating the design, production and sales of automatic screw feeding machines. The automatic wire feeder developed by the company is applied to the production and assembly process of plastics, hardware, electronics, toys, digital, home appliances, computers and other industries. Gewei has a professional R&D team that specializes in providing screw fastening solutions.